Wholesaler of a wide range of products which include c 32 anchor single pole mcb and c 16 anchor electrical mcb double pole.

C 32 Anchor Single Pole MCB

REQUEST CALLBACK

C 32 Anchor Single Pole MCB
  • C 32 Anchor Single Pole MCB
  • C 32 Anchor Single Pole MCB
  • C 32 Anchor Single Pole MCB
  • C 32 Anchor Single Pole MCB
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 55 / PieceGet Latest Price

Product Brochure
Product Details:
Minimum Order Quantity100 Piece
No.of PolesSingle Pole
Rated Current16A
TypeC Curve
Breaking Capacity10 kA
Normal Ambient Temperature30 C
Tripping MechanismThermal and Magnetic Type
MountingOn DIN Rail (35mm X 7.5 mm)
Service Short Circuit Breaking Capacity7500A
Energy LimitationClass 3
Rated Impulse Voltage4kV
Rated Voltage(Ue)SP, TP+N: AC 240V
Rated Frequency(f) Hz50 Hz
Rated Short Circuit Breaking Capacity10000A
Dielectric Strength2000V for 1 minute
Rated Current(ln)63A

  • State of the art design: Elegant appearance, cover and handle in arc shape for comfortable operation. Contact position indicating window (Clear ON-OFF indicator)
  • Three level indications For ON, OFF & TRIP (Under Fault)
  • Rated short circuit capacity: 10000A (10kA)
  • Trip free mechanism
  • High speed and high breaking capacity mechanism.
  • Terminal block with safety shutter: It prevents wrong wiring & burning of terminals.
  • High speed wiping contact structure.
  • Bi-connect terminals at both sides give a choice of using either a busbar or cable to make the connection.
  • Environment-Friendly, Meets the RoHS Compliance defined by the European Standards.
  • Power loss values are much lower than the specified values of IS/IEC making it the most energy-efficient MCB.
Yes! I am interested

C 16 Anchor Electrical MCB Double Pole

REQUEST CALLBACK

C 16 Anchor Electrical MCB  Double Pole
  • C 16 Anchor Electrical MCB  Double Pole
  • C 16 Anchor Electrical MCB  Double Pole
  • C 16 Anchor Electrical MCB  Double Pole
  • C 16 Anchor Electrical MCB  Double Pole
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 75 / PieceGet Latest Price

Product Brochure
Product Details:
Minimum Order Quantity100 Piece
Trip fault IndicationMid Trip Feature
Energy Limiting ClassClass - 3
Ambient Temperature55 C
PolesSP, SP+N, DP, TP, TP+N, FP
Rated Insulation Voltage(Ui)660 V~
Standard Rated Current(In)63A
Rated Short Circuit Breaking Capacity(Icn)10000A(10kA)
Terminal Capacity35sq mm
BrandAnchor
Watt LossAs per the IS/IEC Standards
Rated Frequency(f)50Hz
Rated Voltage(Ue)415 V AC

  • Positive Contact Indication:
  • Uno MCB Has A Clearly Visible Contact Position Indicator To Identify The Real Positions Of Contacts Inside The MCB.
  • Breaking Capacity 10ka:
  • The Breaker Can Break High Short Circuit Fault Under The Conditions Of 3 Phase Fault Or Phase - Neutral Fault, Voltage Dip. The Uno MCB Can Protect Equipment By Opening The Contacts Even If The High Current Of 10ka Appears.
  • Trip Indication By Mid Trip:
  • Uno MCB 10ka Is Equipped With Trip Indication Features With Mid Trip Functionality. This Is An Inbuilt Feature Reflecting The Difference Between Off And Trip (During A Fault) Of MCB.
  • Current Limit Class-3:
  • Uno MCB Is Designed To Allow Minimum Let Through Energy In Case Of Faults. It Operates With High-speed Mechanism In Which Electrodynamic Forces Set Up By The Heavy Current Due To Short-circuit, Separates The Contacts Several Times Faster Before It Could Reach The Peak Value, Thus Suppressing The High Current.
  • Energy Efficient:
  • Uno MCB Has Lower Wattage Loss Values As Compared To The Specification Of Is/iec Standards. Due To Lower Wattage Loss, It Can Be Termed As An Energy Efficient.
  • Large Termination Size And Dual Termination:
  • Uno MCB Has A High Terminal Capacity Of 35 Sq.mm That Allows Using Aluminium Conductors Or Bus- Bars For Connection & Bi- Connect Termination That Allows Connection Of Either Cable Or Bus - Bar For Better Flexibility.
  • Ip 20 Degree Protection:
  • Finger Proof Terminals Eliminate Chances Of Accidental Contact With Live Parts. All The Live Parts Are Shrouded/ Inaccessible; Ensuring Safety Of Installers.
  • Padlocking Facility:
  • Dolly Are Padlock Because Of Purely Safety Purpose During The Maintenance 
  • Off Position For Person Safety During Maintenance.
  • On Position For The Extremely Critical Load.
  • Air Circulation:
  • When Two Or More Poles Are Placed Adjacent To Each Other.the Breathing Channels Are So Profiled That The Air Circulates Around The Individual Pole, Resulting In Cooler Operation.
Yes! I am interested

 
X


Explore More Products

Contact via E-mail
Contact via SMS
Shubham Aggarwal (CEO)
Shree Ganesh Enterprises
Shop No 155, Ground Floor, Block-III Ganga Shoping Complex, Sector-29,Gautam Buddha Nagar
Noida - 201301, Gautam Buddha Nagar, Uttar Pradesh, India
Call Us: 
Call Response Rate: 54%
Share Us :



Home  |   Profile   |  Our Products  |  Site Map  |   Contact Us

© Shree Ganesh Enterprises. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Shree Ganesh  Enterprises